PCT QUANTITATIVE TEST KIT

Price: On Request
Model:
SAVANT-003

Do you wish to get an estimate or quote for PCT QUANTITATIVE TEST KIT with Model No. SAVANT-003 from Beijing Savant Biotechnology Co. Ltd. or wish to get an estimate of all similar medical device or medical equipment? Please press the link below and sit back and relax while we at Hospytek connect to you with all medical device vendors and medical device brands selling PCT QUANTITATIVE TEST KIT.

Powered with Hospytek Vendor Module, Our Vendors can submit a quote in less than 5 seconds, you can chat with them to discuss the specification of PCT QUANTITATIVE TEST KIT by accessing MY ACCOUNT (on the top right corner of your screen) after adding your required details in the form (which will appear once you click the link below).

By clicking below you would:

  • Get a variety in quality with variety in pricing.
  • Get contact details of all relevant vendors of PCT QUANTITATIVE TEST KIT in your email.
  • Be able to review the vendors through our refined rating system.
  • Be able to send request for quote for multiple medical devices.
  • BE ABLE TO SIGN UP WITH HOSPYTEK AS AN END USER FOR ABSOLUTELY FREE.
Method: Fluorescence Immuno Chromatography
Sample: whole blood, serum, plasma 
Main Components:10/20/50 tests in each box, 1Introduction Book, 1 bottle of sample diluent buffer 50 ml, 1 IC card with standard curve.
Storage Temperature: 10-30C
Validation: 12 months
Reference normal value: <0.11ng/ml
1. Physical Performance: the test strip should be neat and complete, no burr, no damage, no pollution; materials     attached firmly; the width of the test strip 3mm; fluid migration velocity should be not less than 10 mm/min.
2. Accuracy: recovery rate should be between 85% - 115%.
3. Linear: linear range is0.150ng/mL, correlation coefficient (r) shall be not less than 0.99.
4. Intra Precision: CV % should be no higher than 15.0%.
5. Inter Precision: R %should be no higher than 15.0%.
6. Blank Limit of Detection: LOD should be no higher than 0.1ng/mL.
7. Detect cross reaction substance of 100ug/mL CRP and 10ng/mL calcitonin, the result should be 0.1ng/m
1. Take out the test strip at room temperature(18-28), flat on the table.
2. Take out the IC card, put the IC card on inductive position of analyzer, the system will read the information of     standard curve in the card and save in the analyzer.
3. Select the curves are consistent with the project and the batch number information before testing
4. Pipe50 L diluted sample in each test strip, wait 15 minutes at the room temperature, and then insert into     the Savant - 100 analyzer for testing, the instrument automatically calculate and show the sample concentration.